Medically Approved DC-DC Converters from 1W to 20W
-
JHL06
Features
- International Medical Approvals
- 4000 VAC Reinforced Insulation
- Meets IEC60601-1, 3rd Edition
- 2 MOPP Isolation at 250 VAC
- 2 μA Patient Leakage Current
- DIP24 Package
- EN55011 Level A With No External Components
- 3 Year Warranty
JHL06 Series 6 Watts. DIP24 plastic package. 10-17V or 20-30V DC Input. Single & dual 5V to 15V regulated output versions. 4kVAC reinforced isolation. Worldwide medical safety approvals. -
JHM06
Features
- Regulated single & dual outputs
- 1.5:1 input range
- Single outputs 5.0 to 15VDC
- Dual outputs ±12 & ±15VDC
- DIP24 package
- International medical safety approvals
- 3.0kVAC reinforced isolation
- 2μA patient leakage current
- EN55011 Class A with no external components
- -20°C to +100°C operating temperature
- Full power to +60°C
- 3 year warranty
JHM06 Series 6 Watts. DIP24 plastic package. 10-17V or 20-30V DC Input. Single & dual 5V to 15V regulated output versions. 3kVAC reinforced isolation Worldwide medical safety approvals. -
JHM10
Features
- International Medical Approvals
- 4000 VAC Reinforced Insulation
- Meets IEC60601-1
- 2 μA Patient Leakage Current
- DIP-24 Package
- EN55011 Level A With No External Components
- 3 Year Warranty
JHM10 Series 10 Watts. DIP24 plastic package. 2:1 5V, 12V or 24V DC Input. Single & dual 5V to 15V regulated output versions. 4kVAC reinforced isolation. Worldwide medical safety approvals. -
JHM15
Features
- International Medical Approvals
- 4000 VAC Reinforced Insulation
- 2 x MOPP
- Medical Approval, IEC60601-1, 3rd Edition
- 2 μA Patient Leakage Current
- Compact 1 x 1.6” Footprint
- EN55011 Level A With No External Components
- 3 Year Warranty
JHM15 Series 15 Watts. 1.6 x 1” plastic package. 2:1, 12V or 24V DC Input. Single & dual 5V to 15V regulated output versions. 4kVAC reinforced isolation. Worldwide medical safety approvals. -
JHM20
Features
- Regulated single & dual outputs from 5 to 30VDC
- Single outputs trimmable ±10%
- 2:1 Input range
- 2” x 1” footprint PCB mount
- International medical approvals
- 4kVAC reinforced isolation
- 2 x MOPP @ 250VAC working voltage
- 2.5µA Patient leakage current
- Medical approval, IEC60601-1, 3rd Edition including risk management
- EN55011 Class A with no external components
- -40°C to +80°C operating temperature
- Full power to +60°C
- 3 year warranty
JHM20 Series 20 Watts. 2 x 1” plastic package. 2:1, 12V, 24V or 48V DC Input. Single & dual 5V to 15V regulated output versions. 4kVAC reinforced isolation. Worldwide medical safety approvals.
-
JHM30
Features
- Regulated single & dual outputs from 5 to 30VDC
- 2:1 input range
- Compact 50.8 x 25.4mm (2” x 1”) PCB mount package
- 10% trim on single output versions
- IEC60601-1 medical safety agency approvals
- 4kVAC reinforced isolation
- 2 x MOPP at 250VAC
- 2μA patient leakage current
- EN55011 class A with no external components
- Short circuit, overload & overvoltage protection
- -40°C to +80°C operating temperature
- 3 year warranty
JHM30 Series 30 Watts. 2 x 1” plastic package. 2:1, 12V, 24V or 48V DC Input. Single & dual 5V to 15V regulated output versions. 4kVAC reinforced isolation. Worldwide medical safety approvals. -
JMR03
Features
- Regulated single & dual outputs
- World wide medical certification
- 4:1 input range
- Compact DIP16 package
- 5.0kVAC isolation
- 2 x MOPP at 250VAC working voltage
- Remote On/Off
- -40°C to +90°C operation
- 3 year warranty
JMR03 Series 3.5 Watts. DIP16 plastic package. 4:1, 12V, 24V or 48V DC Input. Single & dual 5V to 15V regulated output versions. 5kVAC reinforced isolation. Worldwide medical safety approvals. -
JMR10
Features
- Regulated single & dual outputs from 5 to 30VDC
- 4:1 input range
- Ultra-compact DIP24 PCB mount package
- Low no-load power
- 10% trim in single output versions
- IEC60601-1 medical safety agency approvals
- 5kVAC reinforced isolation
- 2 x MOPP at 250VAC
- 2µA patient leakage current
- Remote On/Off
- Short circuit, overload & overvoltage protection
- -40°C to +100°C operating temperature
- 3 year warranty
JMR10 Series 10 Watts. DIP24 plastic package. 4:1, 12V, 24V or 48V DC Input. Single & dual 5V to 15V regulated output versions. 5kVAC reinforced isolation. Worldwide medical safety approvals. -
JMR20
Features
- Regulated single & dual outputs from 5 to 30VDC
- 4:1 input range
- Compact 40.6 x 25.4mm (1" x 1.6") PCB mount package
- Low no-load power
- 10% trim on single output versions
- IEC60601-1 medical safety approvals
- 5kVAC reinforced isolation
- 2 x MOPP at 250VAC
- 2µA patient leakage current
- Remote On/Off
- Short circuit, overload & overvoltage protection
- -40°C to +100°C operating temperature
- 3 year warranty
JMR20 Series 20 Watts. 1.6 x 1” plastic package. 4:1, 24V or 48V DC Input. Single & dual 5V to 15V regulated output versions. 5kVAC reinforced isolation. Worldwide medical safety approvals. -
JTD15
Features
- Regulated single outputs 3.3 to 15VDC
- Regulated dual outputs ±5, ±12 & ±15VDC
- 4:1 input range
- Output trim ±10% for single output models
- 40.6 x 25.4mm (1.6” x 1”) footprint, 10.4mm (0.41”) profile
- 3.0kVDC isolation
- Remote On/Off
- -40°C to +100°C operating temperature
- Full power to +70°C
- 3 year warranty
JTD15 Series 15 Watts. 1.6 x 1” copper package. 4:1, 24V or 48V DC Input. Single & dual 5V to 15V regulated output versions. 3kVAC reinforced isolation. Worldwide medical safety approvals.
Total of 21 results